Continuous power handling
Voice coil diameter
Magnet material
 
 
 
 

Features

  • 500 W continuous program power capacity
  • 64 mm (2.5 in) copper voice coil
  • 50 - 3000 Hz response
  • 98 dB sensitivity

Specifications

  • Nominal Diameter320 mm (12.0 in)
  • Nominal Impedance8 Ω
  • Minimum Impedance6.3 Ω
  • Nominal Power Handling1250 W
  • Continuous power handling2500 W
  • Sensitivity (1W/1m)398.0 dB
  • Frequency Range50 - 3000 Hz
  • Voice Coil Diameter64 mm (2.5 in)
  • Winding MaterialCopper
  • Former MaterialGlass Fibre
  • Winding Depth13.0 mm (0.51 in)
  • Magnetic Gap Depth8.0 mm (0.31 in)
  • Flux Density1.15 T

Design

  • Surround ShapeDouble Roll
  • Cone ShapeExponential
  • Magnet MaterialNeodymium Inside Slug
  • SpiderSingle
  • Pole DesignStraight Pole
  • Woofer Cone TreatmentWP Waterproof Front Side
  • Recommended Enclosure40.0 dm3 (1.41 ft3)
  • Recommended Tuning64 Hz

Parameters4

  • Resonance Frequency52 Hz
  • Re5.5 Ω
  • Qes0.32
  • Qms4.3
  • Qts0.3
  • Vas64.0 dm3 (2.25 ft3)
  • Sd522.0 cm2 (80.9 in2)
  • η₀3.4 %
  • Xmax± 4.5 mm
  • Xvar± 6.0 mm
  • Mms55.0 g
  • Bl17.5 Txm
  • Le1.1 mH
  • EBP162 Hz

Mounting and Shipping Info

  • Overall Diameter313 mm (12.32 in)
  • Bolt Circle Diameter299 mm (11.77 in)
  • Baffle Cutout Diameter282.0 mm (11.1 in)
  • Depth133 mm (5.24 in)
  • Flange and Gasket Thickness9 mm (0.35 in)
  • Air Volume Occupied by Driver2.0 dm3 (0.07 ft3)
  • Net Weight1.9 kg (4.2 lb)
  • Shipping Units1
  • Shipping Weight2.8 kg (6.17 lb)
  • Shipping Box360x360x200 mm (14.17x14.17x7.87 in)

Service Kit

  • 2 hours test made with continuous pink noise signal within the range Fs-10Fs. Power calculated on rated minumum impedance. Loudspeaker in free air.
  • Power on Continuous Program is defined as 3 dB greater than the Nominal rating.
  • Applied RMS Voltage is set to 2.83 V for 8 ohms Nominal Impedance.
  • Thiele-Small parameters are measured after a high level 20 Hz sine wave preconditioning test.