X
MENU

Products

Browse
Compare
Products
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
back
15_10_17_64_6fhx51rear_2b15_10_17_350_file15_10_17_386_file
Diaphragm material
Magnet material
LF Voice Coil Diameter
HF Voice Coil Diameter
LF Continuous Power Handling
HF Continuous Power Handling
 
 
 
 
 
 
 

Features

  • 300 W continuous program power capacity
  • 70° nominal coverage
  • 85 - 18000 Hz response
  • 93 dB sensitivity
  • 20.1 mm (0.79”) HF unit exit diameter

Specifications

  • Nominal Diameter170 mm (6.5 in)
  • Nominal Impedance8 Ω
  • Minimum Impedance LF6.5 Ω
  • Minimum Impedance HF7.0 Ω
  • Frequency Range85 - 18000 Hz
  • Dispersion Angle170 °
  • Woofer Cone TreatmentWP Waterproof Front Side
  • Magnet MaterialFerrite (LF) - Neodym. Ring (HF)

Specifications LF unit

  • LF Sensitivity293.0 dB
  • LF Nominal Power Handling3150 W
  • LF Continuous Power Handling4300 W
  • LF Voice Coil Diameter51 mm (2.0 in)
  • LF Winding MaterialCopper
  • LF Flux Density1.05 T
  • Former MaterialKapton
  • Winding Depth13.0 mm (0.51 in)
  • Magnetic Gap Depth6.0 mm (0.24 in)

Specifications HF unit

  • HF Sensitivity5108.5 dB
  • HF Nominal Power Handling610 W
  • HF Continuous Power Handling720 W
  • HF Voice Coil Diameter25 mm (1.0 in)
  • HF Winding MaterialAluminium
  • HF Flux Density1.65 T
  • Diaphragm MaterialPolyester
  • Recommended Crossover82.5 kHz
  • Inductance0.1 mH

Parameters

  • Resonance Frequency85 Hz
  • Re5.5 Ω
  • Qes0.4
  • Qms7.8
  • Qts0.37
  • Vas5.0 dm3 (0.18 ft3)
  • Sd132.0 cm2 (20.5 in2)
  • η₀0.83 %
  • Xmax± 5.0 mm
  • Xvar± 5.7 mm
  • Mms16.0 g
  • Bl11.3 Txm
  • Le1.0 mH
  • EBP212 Hz

Mounting and Shipping Info

  • Overall Diameter187 mm (7.4 in)
  • Bolt Circle Diameter172 mm (6.7 in)
  • Baffle Cutout Diameter146 mm (5.75 in)
  • Depth122 mm (4.8 in)
  • Flange and Gasket Thickness12 mm (0.47 in)
  • Net Weight2.6 kg (5.73 lb)
  • Shipping Units1
  • Shipping Weight3.05 kg (6.72 lb)
  • Shipping Box255x255x150 mm (10.04x10.04x5.91 in)

Service Kit

  • Included by –6 dB down points.
  • Applied RMS Voltage is set to 2.83V.
  • 2 hours test made with continuous pink noise signal within the range Fs-10Fs. Power calculated on rated minimum impedance. Loudspeaker in free air.
  • Power on Continuous Program is defined as 3 dB greater than the Nominal rating.
  • Applied RMS Voltage is set to 2.83V.
  • 2 hour test made with continuous pink noise signal within the range from the recommended crossover frequency to 20 kHz. Power calculated on rated minimum impedance. Loudspeaker in free air.
  • Power on Continuous Program is defined as 3 dB greater than the Nominal rating.
  • 12 dB/oct. or higher slope high-pass filter.